Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Page Properties

Release Version

Centrix R105

Release Date (Staging)

TBD

Release Date (Production)

TBD

Summary

Table of Contents
minLevel1
maxLevel7
excludeSummary.*
Jira Legacy
serverSystem JIRA
columnskey,summary,type,assignee,status,resolution
maximumIssues1000
jqlQueryproject = Centrix AND fixVersion != TimeOrder AND (fixVersion IN ("Centrix R105", "Centrix R106") OR resolutiondate > "2022/02/10") AND resolution = Fixed AND key NOT IN (CENTRIX-4680,CENTRIX-4654,CENTRIX-4639,CENTRIX-4628,CENTRIX-4636,CENTRIX-4258,CENTRIX-4396,CENTRIX-4644,CENTRIX-4510,CENTRIX-4631,CENTRIX-3099,CENTRIX-4323,CENTRIX-4635,CENTRIX-4627,CENTRIX-4511,CENTRIX-4586,CENTRIX-4588,CENTRIX-4698,CENTRIX-4691,CENTRIX-4722,CENTRIX-4723,CENTRIX-4607,CENTRIX-4702,CENTRIX-4719,CENTRIX-4724,CENTRIX-4600,CENTRIX-4701,CENTRIX-4703,CENTRIX-4741,CENTRIX-4761,CENTRIX-4648) ORDER BY resolutiondate ASC
serverId588b3277-2d3f-3f93-8553-28aac6672408

Assets

Signals - Aspect On Approach

A new ‘Aspect On Approach’ feature has been added for 2/3 and 4 Aspect Signals which records the visible aspect for when a train approaches the signal.

Image Added
  • A pie chart has been added to the Health Tab on the Asset Playback View.

  • This chart shows which aspects were visible in relation to each other for all approaches over the previous 30 days.

Image Added
  • A new Aspect On Approach report has also been added which shows similar graphs to the the Asset Health page.

  • The report allows you define the signals and the time range.

Ebi Track 400 Receiver

Ebi Track 400 receivers have been updated to automatically generate a score indicating the health of the asset from 100% (healthy) to 0% (not working).

Image Added
  • A plot of health score over time has been added to the Health Tab of the Asset Playback View.

The Ebi Track 400 Occupation alarm has been removed and the asset health alarm should be used instead to alert on poorly performing Ebi Track 400 assets.

Image Added
  • The Asset Health alarm can be automatically generated from the Alarms Tab on the Asset Playback View

Image Added
  • The Track Circuit Alarm Wizard can also be used to automatically generate the alarms.

  • The Alarm Sensitivity varies the asset health level at which the alarm is triggered

Image Added
  • The Advanced Configuration is initially hidden and can be accessed by clicking the expand button.

  • The parameters in this configuration refines the asset health score calculation.

  • The default values for the Advanced Configuration are the recommended values which should be sufficent for most Ebi Track 400 assets.

  • The advanced configuration parameters are also editable in the Asset Edit page.

Minor amendments and fixed issues