Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Unbox & Mount the S-LX system

  • Carefully remove the S-LX system from its packaging

  • The system shall already be mounted on DIN rail, or attached to a 19 inch rack shelf

  • Antenna and accessory cables will be packed separately.

  • Mount the DIN rail in the desired location, or move the DIN rail mounted equipment onto an alternative rail.

  • The DIN rail may be cut to size. If doing so ensure that all sharp edges are deburred.

  • When supplied in a 19 inch rack, install the rack into an appropriate cabinet.

Antenna Installation

  • Antenna and antenna cable are supplied separately.

  • Mount the antenna external to the building

  • Never mount antenna inside an equipment enclosure or building

  • The antenna must be placed a minimum of 3 meters from sensitive electronic signalling equipment such as SSI.

  • The antenna features a magnetic mounting base. If this is not suitable, contact MPEC to discuss alternate mounting arrangements.

  • The antenna is to be mounted upright, with the “whip” element pointing skyward.

  • Ideally the antenna shall be placed clear of large structures and earthworks.

  • Bear in mind during placement that the antenna may need relocating during commissioning if inadequate signal strength is available.

  • A minimum12 mm circular aperture is required to route the antenna cable into the building / enclosure.

  • If the building or enclosure structure must be pierced to run the antenna cable, ensure this is done in a responsible manner using appropriate tools. Any new openings must be appropriately sealed against moisture ingress and rodent attack.

  • route the antenna cable using appropriate cable management from antenna to SLX device.

  • Avoid sharp radius bends and never bend the antenna cable tighter than a 13mm radius.

  • Avoid running the antenna cable directly parallel and close to sensitive digital signal cables, such as SSI data links.

  • Do not attempt to shorten or lengthen the cable unless competent to do so and in possession of the appropriate tools and connectors.

  • MPEC offer a range of antenna cable lengths, so please contact MPEC if the standard 5m cable is inappropriate.

  • Hand tighten the hexagonal SMA connector to terminal W1 of the S-LX compute module. Do not use tools to over-tighten.

  • Hand tighten the round TNC connector to the antenna base. Do not use tools to over-tighten.

Connect AC Power Supply

Connect Serial, Ethernet or

...

USB Connection

Commissioning

Energise Power Supply

...