Page Properties
Release VersionCentrix R32
Release Date (Staging) 
Release Date (Production) 
Summary
  • Improvements to sequence timing report
  • Support for BBRail Relay ALERT loggers
  • Timezone fixes

 

Sequence Timing Report Improvements

We have made further improvements to the sequence timing report to make creating reports easier and quicker.

 

BBRail Relay ALERT Loggers

Centrix now has the capability to extract data remotely from BBRail Relay ALERT data loggers. This functionality is currently experimental as we've had limited access to existing hardware. If you'd like to trial a Relay ALERT logger on Centrix, please get in touch.

Warning

We have observed issues with the data from Relay ALERT loggers that will result in potentially unexpected behaviour during replay or alert configuration;

  • Time-stamping of events from the Relay ALERT data logger do not appear to be correct. We believe events appear in order in the data file, in many occasions the timestamp of the event goes backwards between events.
  • The first event in the data file can hold a significantly delayed timestamp (~5 seconds). We believe this is caused by the logger flushing the initial states and then time-stamping any events it holds in the queue. As a result, you can find mis-fired alerts such as "Track Flick".